CERN Accelerating science

CMS Detector Performance Summaries

Darreres entrades:
2024-11-25
11:18
Discharge Studies in a CMS ME0 GEM Detector /CMS Collaboration
The LHC is undergoing an upgrade to increase the instantaneous luminosity by half an order of magnitude; as a result, several detector systems are undergoing upgrades to operate at this higher luminosity. One such upgrade is the introduction of the ME0 GEM detectors in the endcap muon system of the CMS detector, which will extend pseudorapidity acceptance for muons to $\lvert\eta\rvert = 2.8$. [...]
CMS-DP-2024-123; CERN-CMS-DP-2024-123.- Geneva : CERN, 2024 - 11 p. Fulltext: PDF;

Registre complet - Registres semblants
2024-11-25
11:18
Level-1 Trigger Performance in 2024 Proton-Proton Collisions at $\sqrt{s} = 13.6$ TeV /CMS Collaboration
In 2024, the CMS experiment collected a record-large data set of proton-proton collisions at $\sqrt{s} = 13.6$ TeV, corresponding to an integrated luminosity of 114 $\mathrm{fb}^{-1}$. This note summarizes the performance of the CMS Level-1 Trigger system to identify and select muons, jets, transverge energy sums, electrons/photons, and hadronically decaying tau leptons in this data set..
CMS-DP-2024-122; CERN-CMS-DP-2024-122.- Geneva : CERN, 2024 - 35 p. Fulltext: PDF;

Registre complet - Registres semblants
2024-11-25
11:18
Model-Independent Real-Time Anomaly Detection at the CMS Level-1 Calorimeter Trigger with CICADA /CMS Collaboration
In the search for new physics, real-time detection of anomalous events is critical for maximizing the discovery potential at the LHC. CICADA (Calorimeter Image Convolutional Anomaly Detection Algorithm) is a novel CMS trigger algorithm operating at the 40 MHz collision rate. [...]
CMS-DP-2024-121; CERN-CMS-DP-2024-121.- Geneva : CERN, 2024 - 21 p. Fulltext: PDF;

Registre complet - Registres semblants
2024-11-20
13:22
GE1/1 electronics performance /CMS Collaboration
We report on the operational performance and reliability of GE1/1, a new muon tracking and triggering station made of Triple-GEM detectors installed in the most forward region of the CMS muon spectrometer as part of the Phase-2 upgrades for LHC Run-3. The GE1/1 station, comprising 144 Triple-GEM detectors, has been collecting data since 2022. [...]
CMS-DP-2024-120; CERN-CMS-DP-2024-120.- Geneva : CERN, 2024 - 10 p. Fulltext: PDF;

Registre complet - Registres semblants
2024-11-11
14:50
Rate capability of CMS ME0 stack at the GIF++ /CMS Collaboration
A ME0 station of 6 layers of triple-GEM detectors will be built to instrument the very forward region of both CMS end-caps. The first 4-layer stack has been assembled and operated in the 904 laboratory as well as in test beams. The goal of this analysis is to determine the rate capability of the single GEM chambers in a GIF++ test beam campaign in July 2023..
CMS-DP-2024-119; CERN-CMS-DP-2024-119.- Geneva : CERN, 2024 - 11 p. Fulltext: PDF;

Registre complet - Registres semblants
2024-11-11
14:50
PPS Performance 2024 Efficiency and two-arm vertex resolution with timing detectors /CMS Collaboration
The Precision Proton Spectrometer (PPS) is a forward-proton spectrometer using near- beam detectors (inside Roman Pots, RPs) located symmetrically on both sides of IP5 at a distance of about 220 m. In addition to the tracking system, the timing detectors measure the Time-Of-Flight (TOF) of the protons produced in central exclusive interactions. In 2024, one cylindrical and one box RPs on each sector were equipped with four double-diamond planes. This note describes: the efficiency of single sensors and of the TOF system; the resolution of the timing system in two-arm events, where both interacting protons are detected by the PPS detectors. Using low pileup data ($\mu$ = interactions/crossing = 1) and selecting central diffractive events a strong correlation is observed between the time difference of the protons detected in PPS, and the longitudinal vertex position reconstructed in the central CMS tracker..
CMS-DP-2024-118; CERN-CMS-DP-2024-118.- Geneva : CERN, 2024 - 22 p. Fulltext: PDF;

Registre complet - Registres semblants
2024-11-11
14:50
Study of correlation between baseline current and Hit Rate in GE1/1 chambers at the CMS Experiment /CMS Collaboration
The phase-II upgrade of the CMS Muon System includes the addition of three new Gas Electron Multiplier (GEM) stations --- GE1/1, GE2/1, and ME0 --- to extend the detector's acceptance up to a pseudorapidity of $\lvert \eta \rvert \sim 2.8$. Achieving this requires that the detectors must tolerate the high levels of background radiation expected in the forward endcap regions for the High-Luminosity LHC, with a high rate capability as part of their requirements. [...]
CMS-DP-2024-117; CERN-CMS-DP-2024-117.- Geneva : CERN, 2024 - 16 p. Fulltext: PDF;

Registre complet - Registres semblants
2024-11-11
14:50
Verification of iRPC Quality Control Test Results /CMS Collaboration
Results from the verification of iRPC Quality Control Test
CMS-DP-2024-116; CERN-CMS-DP-2024-116.- Geneva : CERN, 2024 - 10 p. Fulltext: PDF;

Registre complet - Registres semblants
2024-11-11
14:50
Threshold calibration of iRPC FEB $\newline$ Inclusion of RPCs in Phase 2 BMT Layer 1 /CMS Collaboration
Results from the threshold calibration of iRPC FEB
CMS-DP-2024-115; CERN-CMS-DP-2024-115.- Geneva : CERN, 2024 - 6 p. Fulltext: PDF;

Registre complet - Registres semblants
2024-11-11
14:50
Super Trigger Primitives RPC-DT Timing Inclusion of RPCs in Phase 2 BMT Layer 1 /CMS Collaboration
Results from the studies on the Super Trigger Primitives RPC-DT Timing..
CMS-DP-2024-114; CERN-CMS-DP-2024-114.- Geneva : CERN, 2024 - 7 p. Fulltext: PDF;

Registre complet - Registres semblants