2023-03-25 04:19 |
Подробен запис - Подобни записи
|
2023-03-25 04:13 |
|
MQXFA Final Design Report
/ Ambrosio, Giorgio (Fermilab) ; Amm, Kathleen (Brookhaven) ; Anerella, Mike (Brookhaven) ; Apollinari, Giorgio (Fermilab) ; Baldini, Maria (Fermilab) ; Yahia, Anis Ben (Brookhaven) ; Blowers, James (Fermilab) ; Carcagno, Ruben (Fermilab) ; Cheng, Daniel (LBL, Berkeley) ; Chlachidze, Guram (Fermilab) et al.
The MQXFA Quadrupole magnets will be installed in High Luminosity LHC to form the Q1 and Q3 inner triplet optical elements in front of the interaction points 1 (ATLAS) and 5 (CMS) [...]
arXiv:2203.06723 ; FERMILAB-TM-2773-TD ; US-HiLumi-doc-948.
-
120 p.
Fermilab Library Server - Fulltext - Fulltext
|
Подробен запис - Подобни записи
|
2023-03-17 06:15 |
Подробен запис - Подобни записи
|
2023-03-16 07:28 |
FOCUS: Fast Monte-CarlO Approach to Coherence of Undulator Sources
/ Siano, Mirko (U. Milan (main)) ; Butti, Daniele (CERN) ; Geloni, Gianluca (European XFEL, Hamburg) ; Iriso, Ubaldo (CELLS - ALBA, LLS) ; Lefèvre, Thibaut (CERN) ; Mazzoni, Stefano (CERN) ; Nosych, Andriy (CELLS - ALBA, LLS) ; Paroli, Bruno (U. Milan (main)) ; Potenza, Marco (U. Milan (main)) ; Torino, Laura (CELLS - ALBA, LLS) et al.
We present Fast Monte-CarlO approach to Coherence of Undulator Sources (FOCUS), a new GPU-based code to compute the transverse coherence of X-ray radiation from undulator sources. The code relies on scaled dimension- less quantities and analytic expressions of the electric field emitted by electrons in an undulator. [...]
2022 - 4 p.
- Published in : JACoW IBIC 2022 (2022) 257-260
Fulltext: PDF;
In : 11th International Beam Instrumentation Conference (IBIC 2022), Cracow, Poland, 11 - 15 Sep 2022, pp.257-260
|
Подробен запис - Подобни записи
|
2023-03-16 07:28 |
LINAC4 Laser Profile and Emittance Meter Commissioning
/ Goldblatt, Aurélie (CERN) ; Andreassen, Odd (CERN) ; Boorman, Gary (JAI, UK) ; Bosco, Alessio (JAI, UK) ; Gibson, Stephen (JAI, UK) ; Hofmann, Thomas (Unlisted, CH) ; Roncarolo, Federico (CERN) ; Tagg, Joseph (CERN)
The CERN LINAC4 is now equipped with two laser profile and emittance meters, a basically non destructive measurement of the transverse beam profile, not limited by the beam power density. The light of a pulsed laser is trans- ported through optical fibers and focused into the 160 MeV/c $H^{-}$ beam. [...]
2022 - 5 p.
- Published in : JACoW IBIC 2022 (2022) 357-361
Fulltext: PDF;
In : 11th International Beam Instrumentation Conference (IBIC 2022), Cracow, Poland, 11 - 15 Sep 2022, pp.357-361
|
Подробен запис - Подобни записи
|
2023-03-16 07:28 |
HL-LHC Beam Gas Fluorescence Studies for Transverse Profile Measurement
/ Sedláček, Ondrej (CERN ; Cockcroft Inst. Accel. Sci. Tech. ; U. Liverpool (main)) ; Ady, Marton (CERN) ; Castro Sequeiro, Cristina (CERN) ; Churchman, Ashley (CERN) ; Forck, Peter (Darmstadt, GSI) ; Mazzoni, Stefano (CERN) ; Sameed, Muhammed (CERN) ; Schneider, Gerhard (CERN) ; Sidorowski, Krystian (CERN) ; Stringer, Oliver (Cockcroft Inst. Accel. Sci. Tech. ; U. Liverpool (main)) et al.
In a gas jet monitor, a supersonic gas curtain is injected into the beam pipe and interacts with the charged particle beam. The monitor exploits fluorescence induced by beam-gas interactions, thus providing a minimally invasive transverse profile measurement. [...]
2022 - 4 p.
- Published in : JACoW IBIC 2022 (2022) 261-264
Fulltext: PDF;
In : 11th International Beam Instrumentation Conference (IBIC 2022), Cracow, Poland, 11 - 15 Sep 2022, pp.261-264
|
Подробен запис - Подобни записи
|
2023-03-16 07:28 |
Fast Spill Monitor Studies for the SPS Fixed Target Beams
/ Roncarolo, Federico (CERN) ; Arrutia Sota, Pablo Andreas (CERN) ; Belohrad, David (CERN) ; Bergamaschi, Michele (CERN) ; Calvo Giraldo, Eva (CERN) ; Effinger, Ewald (CERN) ; Fraser, Matthew (CERN) ; Kain, Verena (CERN) ; Martin Nieto, Miguel (CERN) ; Mazzoni, Stefano (CERN) et al.
At the CERN Super Proton Synchrotron (SPS) the proton beam is supplied to the fixed target experiments in the North Area facility (NA) via a slow extraction process, taking place at 400 GeV. The monitoring of the spill quality during the extraction, lasting 4.8 seconds with the present SPS setup, is of high interest for minimising beam losses and providing the users with uniform proton-on-target rates. [...]
2022 - 5 p.
- Published in : JACoW IBIC 2022 (2022) 522-526
Fulltext: PDF;
In : 11th International Beam Instrumentation Conference (IBIC 2022), Cracow, Poland, 11 - 15 Sep 2022, pp.522-526
|
Подробен запис - Подобни записи
|
2023-03-16 07:28 |
Подробен запис - Подобни записи
|
2023-03-16 06:37 |
Electro-Optical BPM Development for High Luminosity LHC
/ Arteche, Alberto (Royal Holloway, U. of London) ; Gibson, Stephen (Royal Holloway, U. of London) ; Lefèvre, Thibaut (CERN) ; Levens, Thomas (CERN)
An Electro-Optic Beam Position Monitor (EO-BPM) is being developed as a high-frequency (up to 10 GHz) diagnostic for crabbing and Head-Tail intra-bunch detection at the HL-LHC. Following an earlier prototype at the SPS that demonstrated single-pickup signals, an upgraded design of an interferometric EO-BPM has been beam-tested at the HiRadMat facility for validation and characterisation studies. [...]
2022 - 5 p.
- Published in : JACoW IBIC 2022 (2022) 181-185
Fulltext: PDF;
In : 11th International Beam Instrumentation Conference (IBIC 2022), Cracow, Poland, 11 - 15 Sep 2022, pp.181-185
|
Подробен запис - Подобни записи
|
2023-02-17 14:53 |
Подробен запис - Подобни записи
|
|
|